Unable to read Identifiers for India

4 posts / 0 new
Last post
Sachin Ambre
Unable to read Identifiers for India

Hello,

I am able to read EDMI MK 6 meter with .net code and read the parameter with Low authentication.

When I tried to read generic profile 1.0.94.91.4.255 with read by range and row it does n't work. So I tried with Read(it,2) and read(it,3) as suggested.

with data index =2, I got the result as {1, frequency}, {1, Voltage} and so on..
But in case of 3, I get list of objects. and value column in it return null.

Kindly help me to read this data from meter.

Kurumi
Kurumi's picture

Hi Sachin,

I believe that your meter is using attribute 0.
It means that your meter is saving all values from the register to one cell and there are there in array.

You need to access data selecting the cell and then get wanted data using array index.

BR,

Mikk

________________________________________
Mikko Kurunsaari
Gurux Ltd
http://www.gurux.fi

Sachin Ambre

Hi Mikko,

Thanks for your reply.. Can you provide code sample for same.

Regards,
Sachin Ambre

Kurumi
Kurumi's picture

Hi,

When you have data in to the buffer you can access it something like this:

object[] row = pg.Buffer[0];
//Update correct cell index.
object[] cell = (object[]) row[1];
object[] value = cell[0];

BR,
Mikko

________________________________________
Mikko Kurunsaari
Gurux Ltd
http://www.gurux.fi